Please use this identifier to cite or link to this item:
acessibilidade
http://hdl.handle.net/20.500.12207/666
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Quaresma, Cláudia | - |
dc.contributor.author | João, F. | - |
dc.contributor.author | Fonseca, M. | - |
dc.contributor.author | Secca, M.F. | - |
dc.contributor.author | Veloso, A. | - |
dc.contributor.author | O'Neil, J.G. | - |
dc.contributor.author | Branco, J. | - |
dc.date.accessioned | 2013-12-19T14:59:29Z | - |
dc.date.available | 2013-12-11 | - |
dc.date.available | 2013-12-19T14:59:29Z | - |
dc.date.issued | 2009-09 | - |
dc.identifier.citation | Quaresma, C., João, F., Fonseca, M., Secca, M. F., Veloso, A., O'Neil, J. G., Branco, J. (2009, Sept. 7-12). Validation of vertebral metrics: A mechanical instrument to evaluate posture of the spinal column. World Congress on Medical Physics and Biomedical Engineering: Diagnostic and Therapeutic Instrumentation, Clinical Engineering, Munich | pt_PT |
dc.identifier.isbn | 978-364203884-6 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.12207/666 | - |
dc.description | World Congress on Medical Physics and Biomedical Engineering: Diagnostic and Therapeutic Instrumentation, Clinical Engineering: Munich, Germany: Sept. 7-12, 2009 | pt_PT |
dc.description.abstract | The purpose of this study is to verify the validity of the instrument Vertebral Metrics, designed to identify X, Y, and Z positions of - each vertebral apophyses, by comparing the results obtained from this instrument with those from an optoelectronic system of Stereophogrammetry, composed of 10 infrared cameras with a sampling frequency of 200 Hz. Methodology: The sample consisted of 11 women aged between 14 and 39 years. After marking the various points in the spinal column, from the 1st cervical vertebra to the 1st sacral vertebra, each woman's backbone was first measured with Vertebral Metrics and then measured with the optoelectronics system. Later, the results obtained with the two instruments were compared. Results: For our analysis we used an ANOVA model with 3 factors (Instrument, Subject and vertebrates) for the intervertebral distance. | pt_PT |
dc.language.iso | eng | pt_PT |
dc.rights | info:eu-repo/semantics/closedAccess | pt_PT |
dc.subject | Biomechanics | pt_PT |
dc.subject | Instrumentation | pt_PT |
dc.subject | Spine | pt_PT |
dc.subject | ANOVA model | pt_PT |
dc.subject | Cervical vertebra | pt_PT |
dc.subject | Infra-red cameras | pt_PT |
dc.subject | Optoelectronic systems | pt_PT |
dc.subject | Sampling frequencies | pt_PT |
dc.subject.classification | Indexação SCOPUS | pt_PT |
dc.title | Validation of vertebral metrics: a mechanical instrument to evaluate posture of the spinal column | pt_PT |
dc.type | conferenceObject | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.relation.publisherversion | http://dx.doi.org/10.1007/978-3-642-03885-3-197 | pt_PT |
degois.publication.firstPage | 711 | pt_PT |
degois.publication.lastPage | 713 | pt_PT |
degois.publication.location | Munich, Germany | pt_PT |
degois.publication.title | IFMBE Proceedings | pt_PT |
Appears in Collections: | D-SA - Comunicações com peer review |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.